License-built in China, this German Ritter Solar 12-tube evacuated tube solar hot water collector is of high build-quality and has been field-proven worldwide. It is built to order as a standard finished product in any quantity directly from the manufacturer.

SKU/Item Number: CPC 12

12-Tube Evacuated Tube Solar Hot  Water Collector with Compound  Parabolic Concentrator (CPC)  

The Product´

This evacuated tube collector was developed especially for solar domestic water heating and for solar backup space heating. The low pressure loss allows several modules to be connected in series. The collectors can be used for open or close loop applications with water or Glycol solution. This evacuated tube collector differs from the ^heat pipe ̄ type collectors commonly found on the market, it allows fluid to circulate through the U-tubes within the evacuated tubes thus reducing localized hot spots and scale buildup. It consists of three main components which are completely pre-assembled:

Evacuated Tubes

CPC Mirrors
Collecting Box with Heat Transfer Unit


The Evacuated Tube...

The evacuated tube is a product that is optimized in geometry and performance. The tubes are composed of two concentric glass tubes which in each case are half spherically closed on one side and fused together on the other side. The gap between the tubes is evacuated and afterwards hermetically plugged (vacuum insulation). In order to make solar power usable, the internal glass tube is provided on its external surface with an environmentally friendly, highly selective layer and thus designed as an absorber. This coating is thus protected within the vacuum gap.It is an aluminum nitrite sputter layer which is characterized by very low emission and very good absorption.

The CPC Mirror...

In order to increase the efficiency of the evacuated tubes, a highly reflecting, weather-proof CPC mirror (Compound Parabolic Concentrator) is placed behind the evacuated tubes. The special mirror geometry ensures that even at unfavorable irradiation angles direct and diffuse sunlight falls onto the absorber. This substantially improves the energy yield of a solar collector. Unfavorable irradiation angles are given at diagonally incoming light (azimuth angle) (no south adjustment of the mounting area, sun progress from east to west, diffuse irradiation).

Collecting Box with Heat Transfer Unit...

The insulated collecting and distribution pipes are located inside the collecting box. The advance or return connection can take place alternatively on the left of or on the right. In each evacuated tube there is a U pipe with direct flow-through that is connected in such a way to the collecting or distribution pipe that each individual evacuated tube exhibits the same hydraulic resistance. This U pipe is pressed to the inside of the evacuated tube with the heat guide plate.

Technical Specifications...
Series
CPC 12 OEM
Number of evacuated tubes
12
η0 (Aperture area),
DIN 4757-4 or EN 12975
%
66,1
c1 with wind, in relation to aperture area
W/(m2k)
0,82
c2 with wind, in relation to aperture area
W/(m2k2)
0,0064
Kθ,trans (50<), in relation to aperture area
1
Kθ,long (50<), in relation to aperture area
0,9
yield forecast (reference location W┨rzburg, Germany, aperture area 3 m2)
kWh/m2a
660
yield forecast (reference location W┨rzburg, Germany, aperture area 5 m2)
kWh/m2a
586
grid measurements
(length, height, depth)
m
1,39 x 1,64 x 0,1
gross area
m2
2,28
aperture area
m2
2,0
absorber capacity
l
1,6
weight
kg
37
max. working pressure burden
bar
10
max. stagnation temperature
<C
295
connection diameter of inlet and outlet tube
mm
15
feeler sleeve
mm
6
material of collector
Al / Cu / glass / silicone
/ PBT / EPDM / TE
material of glass tube
borosilicate
glass 3.3
material of selective absorber coating
Aluminium Nitrite
glass tube (outside and inside thickness/ wall thickness/length of tube)
mm
47/37/1,6/1500
colour (aluminium frame profile,
powder-coated)
RAL
7015
colour (plastic parts)
black
thermal shock test
ITW test no.
02COL282
impact-from-hail test DIN EN 12975-2
T┨V test no.
435/142448
qualification approval number
01-228-770