License-built in China,
this German Ritter Solar 12-tube evacuated tube solar hot water
collector is of high build-quality and has been field-proven worldwide.
It is built to order as a standard finished product in any quantity
directly from the manufacturer.
SKU/Item Number:
CPC 12
|
| 12-Tube
Evacuated Tube Solar Hot Water Collector with Compound Parabolic
Concentrator (CPC) |
|
|
|
|
The
Product´
This
evacuated tube collector was developed especially for solar domestic
water heating and for solar backup space heating. The low pressure
loss allows several modules to be connected in series. The collectors
can be used for open or close loop applications with water or Glycol
solution. This evacuated tube collector differs from the ^heat pipe ̄
type collectors commonly found on the market, it allows fluid to
circulate through the U-tubes within the evacuated tubes thus reducing
localized hot spots and scale buildup. It consists of three main
components which are completely pre-assembled:
,Evacuated
Tubes
,CPC
Mirrors
,Collecting
Box with Heat Transfer Unit
|
 |
|
The Evacuated Tube...
The
evacuated tube is a product that is optimized in geometry and performance.
The tubes are composed of two concentric glass tubes which in each
case are half spherically closed on one side and fused together
on the other side. The gap between the tubes is evacuated and afterwards
hermetically plugged (vacuum insulation). In order to make solar
power usable, the internal glass tube is provided on its external
surface with an environmentally friendly, highly selective layer
and thus designed as an absorber. This coating is thus protected
within the vacuum gap.It is an aluminum nitrite sputter layer which
is characterized by very low emission and very good absorption.
The
CPC Mirror...
In order to increase the efficiency of
the evacuated tubes, a highly reflecting, weather-proof CPC mirror
(Compound Parabolic Concentrator) is placed behind the evacuated
tubes. The special mirror geometry ensures that even at unfavorable
irradiation angles direct and diffuse sunlight falls onto the absorber.
This substantially improves the energy yield of a solar collector.
Unfavorable irradiation angles are given at diagonally incoming
light (azimuth angle) (no south adjustment of the mounting area,
sun progress from east to west, diffuse irradiation).
Collecting
Box with Heat Transfer Unit...
The insulated collecting
and distribution pipes are located inside the collecting box. The
advance or return connection can take place alternatively on the
left of or on the right. In each evacuated tube there is a U pipe
with direct flow-through that is connected in such a way to the
collecting or distribution pipe that each individual evacuated tube
exhibits the same hydraulic resistance. This U pipe is pressed to
the inside of the evacuated tube with the heat guide plate.
|
| Technical
Specifications... |
 |
 |
|
Series
|
|
CPC
12 OEM
|
|
Number
of evacuated tubes
|
|
12
|
|
η0
(Aperture area),
DIN 4757-4 or EN 12975
|
%
|
66,1
|
|
c1
with wind, in relation to aperture area
|
W/(m2k)
|
0,82
|
|
c2
with wind, in relation to aperture area
|
W/(m2k2)
|
0,0064
|
|
Kθ,trans
(50<), in relation to aperture area
|
|
1
|
|
Kθ,long
(50<), in relation to aperture area
|
|
0,9
|
|
yield
forecast (reference location W┨rzburg, Germany, aperture area
3 m2)
|
kWh/m2a
|
660
|
|
yield
forecast (reference location W┨rzburg, Germany, aperture area
5 m2)
|
kWh/m2a
|
586
|
|
grid
measurements
(length, height, depth)
|
m
|
1,39
x 1,64 x 0,1
|
|
gross
area
|
m2
|
2,28
|
|
aperture
area
|
m2
|
2,0
|
|
absorber
capacity
|
l
|
1,6
|
|
weight
|
kg
|
37
|
|
max.
working pressure burden
|
bar
|
10
|
|
max.
stagnation temperature
|
<C
|
295
|
|
connection
diameter of inlet and outlet tube
|
mm
|
15
|
|
feeler
sleeve
|
mm
|
6
|
|
material
of collector
|
|
Al
/ Cu / glass / silicone
/ PBT / EPDM / TE
|
|
material
of glass tube
|
|
borosilicate
glass 3.3
|
|
material
of selective absorber coating
|
|
Aluminium
Nitrite
|
|
glass
tube (outside and inside thickness/ wall thickness/length
of tube)
|
mm
|
47/37/1,6/1500
|
|
colour
(aluminium frame profile,
powder-coated)
|
RAL
|
7015
|
|
colour
(plastic parts)
|
|
black
|
|
thermal
shock test
|
ITW
test no.
|
02COL282
|
|
impact-from-hail
test DIN EN 12975-2
|
T┨V
test no.
|
435/142448
|
|
qualification
approval number
|
|
01-228-770
|
|
EcoGreen
Commerce
168 Tian Shan Zhi Road, Suite 802
Shanghai 200051, P. R. China
Tel: 86-21-6234-7790
Fax: 86-21-6228-8580
E-Mail: postmaster@dalu.com
Home|AboutUs|ContactUs|ProductList
|